            Vivaspin 2 50 kDa MWCO PES 25/pk
            SKU
        
GE/28932257
    Brand
    
            CYTIVA
            
                                            Pre-order (Deliver in 8 to 12 weeks)
                
                    
    
                            Vivaspin™ ultrafiltration spin columns are designed for fast, non-denaturing concentration and desalting of proteins and other biological samples.
                        
                                                                                                    
                        - Ease-of-use: One-step sample concentration in a single tube, for minimal sample handling and reduced sample loss, as well as pH compatibility over a broad range – pH 1 to 9.
 - Sample protection:Â Patented Vivaspin dead-stop technology ensures samples cannot be concentrated to dryness and enables direct concentrate recovery.
 - Ease-of-use:Â One-step sample concentration in a single tube, for minimal sample handling and reduced sample loss.
 - High flow rates:Â And minimal membrane blockage through the vertical polyethersulfone (PES) membrane design.
 - Minimal protein adsorption:Â Thanks to the Vivaspin™ polycarbonate tube design.
 - Wide selection:Â Vivaspin sample concentrators are suitable for sample volumes ranging from 100 μL to 20 mL, with a range of molecular weight cut-off (MWCO) values from Mr 3000 to 100 000.
 - Download the Vivaspin protein concentrator data file to learn more and to determine the right MWCO (molecular weight cut-off) and volume for your enrichment study.
 
Spin column protein concentration – how does it work
Membrane spin columns such as Vivaspin combine the principle of size exclusion with centrifugation to achieve rapid concentration and high recovery of target biomolecules in a single tube. An upper compartment containing sample is separated from the lower compartment by a semipermeable membrane with an appropriate MWCO value chosen to exclude molecules of interest. Centrifugation is applied to force solvent through the membrane, leaving a more concentrated sample in the upper chamber. The Vivaspin column design permits protocols for one-step biomolecule concentration, rapid sample recovery (reverse spin protocol), desalting, and buffer exchange.| Brand | CYTIVA | 
|---|