Welcome to the Refreshed Chemopharm Webstore!
 
SKU
CP/OO/O/P-00652-30
Brand
COLE-PARMER
Pre-order (Deliver in 8 to 12 weeks)

Standard Cole-Parmer 1413US

Login For Price
Traceable conductivity standards are Certified Reference Materials, making one of the most accurate available
  • All Oakton Traceable conductivity standards are NIST-traceable reference materials
  • Supplied with a calibration report from an ISO 17034 and ISO 17025 accredited laboratory
  • These standard solutions let you calibrate conductivity instruments to ensure accuracy
  • If unopened, shelf life is one year; once opened, shelf life will vary by solution value
  • Use when readings are expected to be around 1413 µS/cm

INCLUDES

temperature compensation chart, TDS conversion chart, and NIST-traceable calibration certificate with data.

MORE ABOUT THIS ITEM

-Oakton Traceable conductivity and TDS standards have detailed labels: KCl, NaCl, and 442 conversions, temperature corrections, and certified values referenced to 25°C—convenient!!
-Average accuracy at 25°C is ±0.25 microsiemens for 1, 5, 10 microsiemen (µS) solutions, or ±0.25% for all other solutions. The tested uncertainty is shown on the certificate, whichever is greater
-Conductivity options range from 1 to 200,000 µS/cm
-Batch-tested solutions are lot certified; a few bottles from a single lot are analyzed

METHODS SUPPORTED
-Certified reference material meets test requirements for Federal, State, and local agencies, CAP, ASTM, NCCLS, CLSI, ACS, CLIA, AOAC, EPA, APHA, AWWA, WEF, USGS, USP, and ISO. Traceable Conductivity Standards complies with and is essential for use in these official methods: AOAC 973.40, EPA 120.1, Standard Method 2510 (APHA, AWWA, WEF), ISO 7888, DIN 38404, ASTM D1125, USGS I-1780, USP 645, and for A2LA/NVLAP accreditations/ISO 9000 certifications. Material may be used to calibrate all conductivity meters and to determine all conductivity cell constants.

A2LA ACCREDITATION ISO/IEC 17025:2005 (1750.01)
-To assure accuracy an individually serial-numbered Traceable Certificate is supplied to indicate traceability to standards provided by NIST (National Institute of Standards and Technology) and/or a National Standards Laboratory. A2LA accredited certification provides the highest achievable level of quality assurance, documentation, and accuracy. Conductivity Standards are produced in an A2LA accredited ISO/IEC 17025:2005 (1750.01) calibration laboratory. Additional certifications include ISO 31 (certificate content) and ISO 35 (statistical analysis), plus ISO 9001 (certified quality manufacturer).

Specifications & Description

  • Conductivity Value (µS)1413
  • TDS Value (ppm)933
  • Volume (mL)500
  • Volume (oz)16
  • Conductivity-to-TDS Calibration Values (ppm 442)1000
  • Conductivity-to-TDS Calibration Values (ppm KCl)745
  • Conductivity-to-TDS Calibration Values (ppm NaCl)702
  • DescriptionTraceable Conductivity and TDS Standard, Batch-Tested, 1413 µS; 500 mL
More Information
Brand COLE-PARMER
Write Your Own Review
You're reviewing:Standard Cole-Parmer 1413US
Your Rating
Who Viewed This Also Viewed
  1. Cell Culture Flask with Filtered Cap, 25cm2, PS, TC treated, Sterile, 5 Pcs/Pack, 40 Packs/Case
    Cell Culture Flask with Filtered Cap, 25cm2, PS, TC treated, Sterile, 5 Pcs/Pack, 40 Packs/Case Brand: BIOLOGIX SKU: BX/07-8025
    Login For Price
  2. 10G Class 4 Weight W/NVLAP
    10G Class 4 Weight W/NVLAP Brand: COLE-PARMER SKU: CP/OO/O/P-01029-25
    Login For Price
  3. Bottle Wide-Mouth HDPE 125ml 12/pk
    Bottle Wide-Mouth HDPE 125ml 12/pk Brand: COLE-PARMER SKU: CP/P-06035-39
    Login For Price
  4. No. 6 Filter Circles 18.5cm/100
    No. 6 Filter Circles 18.5cm/100 Brand: WHATMAN SKU: WH/MA/AO/1006185
    Login For Price
  5. Micro Float A-Lyzer 8-10KD 500ul
    Micro Float A-Lyzer 8-10KD 500ul Brand: COLE-PARMER SKU: CP/P-02906-86
    Login For Price