Welcome to the Refreshed Chemopharm Webstore!
 

Standard Cole-Parmer 1000US

SKU
CP/P-00652-48
Brand
COLE-PARMER
Pre-order (Deliver in 8 to 12 weeks)
Login For Price
Traceable conductivity standards are Certified Reference Materials, making one of the most accurate available
  • All Oakton Traceable conductivity standards are NIST-traceable reference materials
  • Supplied with a calibration report from an ISO 17034 and ISO 17025 accredited laboratory
  • These standard solutions let you calibrate conductivity instruments to ensure accuracy
  • If unopened, shelf life is one year; once opened, shelf life will vary by solution value
  • Use when readings are expected to be around 1000 µS/cm

INCLUDES

temperature compensation chart, TDS conversion chart, and NIST-traceable calibration certificate with data.

MORE ABOUT THIS ITEM

-Oakton Traceable conductivity and TDS standards have detailed labels: KCl, NaCl, and 442 conversions, temperature corrections, and certified values referenced to 25°C—convenient!!
-Average accuracy at 25°C is ±0.25 microsiemens for 1, 5, 10 microsiemen (µS) solutions, or ±0.25% for all other solutions. The tested uncertainty is shown on the certificate, whichever is greater
-Conductivity options range from 1 to 200,000 µS/cm
-Individually-tested solutions are certified by the bottle—each bottle is analyzed for the best accuracy

METHODS SUPPORTED
-Certified reference material meets test requirements for Federal, State, and local agencies, CAP, ASTM, NCCLS, CLSI, ACS, CLIA, AOAC, EPA, APHA, AWWA, WEF, USGS, USP, and ISO. Traceable Conductivity Standards complies with and is essential for use in these official methods: AOAC 973.40, EPA 120.1, Standard Method 2510 (APHA, AWWA, WEF), ISO 7888, DIN 38404, ASTM D1125, USGS I-1780, USP 645, and for A2LA/NVLAP accreditations/ISO 9000 certifications. Material may be used to calibrate all conductivity meters and to determine all conductivity cell constants.

A2LA ACCREDITATION ISO/IEC 17025:2005 (1750.01)
-To assure accuracy an individually serial-numbered Traceable Certificate is supplied to indicate traceability to standards provided by NIST (National Institute of Standards and Technology) and/or a National Standards Laboratory. A2LA accredited certification provides the highest achievable level of quality assurance, documentation, and accuracy. Conductivity Standards are produced in an A2LA accredited ISO/IEC 17025:2005 (1750.01) calibration laboratory. Additional certifications include ISO 31 (certificate content) and ISO 35 (statistical analysis), plus ISO 9001 (certified quality manufacturer).

Specifications & Description

  • Conductivity Value (µS)1000
  • Conductivity Value (mS)1
  • TDS Value (ppm)666
  • Volume (mL)500
  • Volume (oz)16
  • DescriptionTraceable Conductivity and TDS Standard, Individually-Tested, 1000 µS; 500 mL
More Information
Brand COLE-PARMER
Write Your Own Review
You're reviewing:Standard Cole-Parmer 1000US
Your Rating
More from COLE-PARMER
Who Viewed This Also Viewed
  1. Eutech CON 2700 Meter with 4-Cell Conductivity Probe (CONSEN9201D),
    Eutech CON 2700 Meter with 4-Cell Conductivity Probe (CONSEN9201D), Brand: EUTECH SKU: EU/BE/CO/CON2700/43S
    Login For Price
  2. Membrane Dialysis 75mm 50`/bx
    Membrane Dialysis 75mm 50`/bx Brand: COLE-PARMER SKU: CP/OO/O/P-02900-45
    Login For Price
  3. Bottles Squre HDPE 250ml 10/pk
    Bottles Squre HDPE 250ml 10/pk Brand: COLE-PARMER SKU: CP/OO/O/P-06019-76
    Login For Price
  4. AA Antibiotic Assay Disc 13mm/1000
    AA Antibiotic Assay Disc 13mm/1000 Brand: WHATMAN SKU: WH/MA/EO/2017013
    Login For Price
  5. Burkle 9695-3050 Titrating burette with shatter protection, 50 mL
    Burkle 9695-3050 Titrating burette with shatter protection, 50 mL Brand: COLE-PARMER SKU: CP/P-06044-52
    Login For Price